Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Microbiol Spectr ; 10(6): e0215822, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36321898

RESUMO

Many cities across the nation are plagued by lead contamination in drinking water. As such, many drinking water utilities have undertaken lead service line (LSL) replacement to prevent further lead contamination. However, given the urgency of lead mitigation, and the socioeconomic challenges associated with LSL replacement, cities have used phosphate-based corrosion inhibitors (i.e., orthophosphate) alongside LSL replacement. While necessary to ensure public health protection from lead contamination, the addition of orthophosphate into an aging and leaking drinking water system may increase the concentration of phosphate leaching into urban streams characterized by century-old failing water infrastructure. Such increases in phosphate availability may cascade into nutrient and microbial community composition shifts. The purpose of this study was to determine how this occurs and to understand whether full-scale distribution system orthophosphate addition impacts the microbial ecology of urban streams. Through monthly collection of water samples from five urban streams before and after orthophosphate addition, significant changes in microbial community composition (16S rRNA amplicon sequencing) and in the relative abundance of typical freshwater taxa were observed. In addition, key microbial phosphorus and nitrogen metabolism genes (e.g., two component regulatory systems) were predicted to change via BugBase. No significant differences in the absolute abundances of total bacteria, Cyanobacteria, and "Candidatus Accumulibacter" were observed. Overall, the findings from this study provide further evidence that urban streams are compromised by unintentional hydrologic connections with drinking water infrastructure. Moreover, our results suggest that infiltration of phosphate-based corrosion inhibitors can impact urban streams and have important, as-yet-overlooked impacts on urban stream microbial communities. IMPORTANCE Elevated lead levels in drinking water supplies are a public health risk. As such, it is imperative for cities to urgently address lead contamination from aging drinking water supplies by way of lead service line replacements and corrosion control methods. However, when applying corrosion control methods, it is also important to consider the chemical and microbiological effects that can occur in natural settings, given that our water infrastructure is aging and more prone to leaks and breaks. Here, we examine the impacts on the microbial ecology of five urban stream systems before and after full-scale distribution system orthophosphate addition. Overall, the results suggest that infiltration of corrosion inhibitors may impact microbial communities; however, future work should be done to ascertain the true impact to protect both public and environmental health.


Assuntos
Água Potável , Rios , Rios/microbiologia , Chumbo/química , Fosfatos , Corrosão , RNA Ribossômico 16S/genética
2.
PLoS One ; 9(10): e110335, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25329300

RESUMO

We report on the contamination of commercial 15-nitrogen (15N) N2 gas stocks with 15N-enriched ammonium, nitrate and/or nitrite, and nitrous oxide. 15N2 gas is used to estimate N2 fixation rates from incubations of environmental samples by monitoring the incorporation of isotopically labeled 15N2 into organic matter. However, the microbial assimilation of bioavailable 15N-labeled N2 gas contaminants, nitrate, nitrite, and ammonium, is liable to lead to the inflation or false detection of N2 fixation rates. 15N2 gas procured from three major suppliers was analyzed for the presence of these 15N-contaminants. Substantial concentrations of 15N-contaminants were detected in four Sigma-Aldrich 15N2 lecture bottles from two discrete batch syntheses. Per mole of 15N2 gas, 34 to 1900 µmoles of 15N-ammonium, 1.8 to 420 µmoles of 15N-nitrate/nitrite, and ≥21 µmoles of 15N-nitrous oxide were detected. One 15N2 lecture bottle from Campro Scientific contained ≥11 µmoles of 15N-nitrous oxide per mole of 15N2 gas, and no detected 15N-nitrate/nitrite at the given experimental 15N2 tracer dilutions. Two Cambridge Isotopes lecture bottles from discrete batch syntheses contained ≥0.81 µmoles 15N-nitrous oxide per mole 15N2, and trace concentrations of 15N-ammonium and 15N-nitrate/nitrite. 15N2 gas equilibrated cultures of the green algae Dunaliella tertiolecta confirmed that the 15N-contaminants are assimilable. A finite-differencing model parameterized using oceanic field conditions typical of N2 fixation assays suggests that the degree of detected 15N-ammonium contamination could yield inferred N2 fixation rates ranging from undetectable, <0.01 nmoles N L(-1) d(-1), to 530 nmoles N L(-1) d(-1), contingent on experimental conditions. These rates are comparable to, or greater than, N2 fixation rates commonly detected in field assays. These results indicate that past reports of N2 fixation should be interpreted with caution, and demonstrate that the purity of commercial 15N2 gas must be ensured prior to use in future N2 fixation rate determinations.


Assuntos
Compostos de Amônio/análise , Técnicas de Química Analítica/normas , Contaminação de Medicamentos , Nitratos/análise , Fixação de Nitrogênio , Isótopos de Nitrogênio/química , Clorófitas/metabolismo , Cromatografia Gasosa , Isótopos de Nitrogênio/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...